800.776.3645
|
- It reflects heat - keeps
buildings warm in Winter and cool in Summer.
- It stops air infiltration - seals drafty
buildings.
- It acts as a vapor barrier.
- It is strong, light weight, clean and does
not degrade over time.
- It is easy and fast to install - usually
saves up to 50% labor time.
- It improves comfort AND saves money.
G U I D E L I N E S F O R A
L L A S T R O - F O I L I N S T
A L L A T I O N S
- ASTRO-FOIL works best when there
is a 3/4' air space on each side of the insulation. (Larger air space
is fine but a smaller one reduces its thermal effectiveness.)
- ASTRO-FOIL should always be installed
on the inside of the structure.
- ASTRO-FOIL will not cure existing
problems. Leaking roofs, rot or mold situations or other moisture or
structural problems should be corrected before installation.
- Any deteriorated wiring should be
replaced prior to installing ASTRO-FOIL.
- ASTRO-FOIL should be at least 3'
from any heat producing fixtures, chimneys, blowers, etc. NEVER install
ASTRO-FOIL directly above lighting or other heat producing devices.
- Always turn off all electricity in
the area when installing ASTRO-FOIL.
 |
ASTRO-FOIL REFLECTIVE
MATERIAL
ASTRO-FOIL reflective installation
consists of two layers of aluminum foil laminated to the
outside of two layers of heavy-duty polyethylene air-bubble
cushioning. These bubbles form trapped air spaces between
the foil surfaces to give the structure excellent 'R' values.
Because ASTRO-FOIL II is also impervious to moisture and
air currents, it is an ideal convection and vapor barrier.
ASTRO-FOIL's surfaces reflect heat in both directions to
keep you warm in the Winter and cooler in Summer.
Some
of the many uses for ASTRO-FOIL
|
In Agricultural Buildings
In Beverage Coolers
In Commercial Buildings
In Confinement Structures
In Industrial Buildings
In Warehouses
In Workshops
In Post Frame Construction
Behind Freezers |
Behind Woodstoves
Behind Refrigeration Coils
For Concrete-Curing Blankets
Under Tents
Under Sleeping Bags
Under Mattresses
As Padded Foot Warmers
As Cargo Liners in Trucks
As A Window Covering |
As A Survival Blanket
As Pharmaceutical Packaging
As Duct Wrap
On Overhead Doors |
|
TECHNICAL
DATA
|
Thickness:
Weight:
Flame Spread
(ASTM E-84-81A):
Fire Rating:
Linear Shrinkage:
Puncture Resistance:
R-Value*:
Emittance C1371:
Reflectance:
Degradation:
U-Value (Btu/ft. 2hro F):
Water Transmission Rate
ASTME96:
Fungi Resistant |
Astro-Foil
5/16' Nominal (8mm)
1.25 oz. per sq. ft. (382 g/m2)
20 Flame/30 Smoke
Class A/Class1
None
66 lbs. per sq. in. (455 kPa)
15 (down) 7.31 (Horiz.) 5.4 (Up)
0.03-0.04
0.96-0.97
0
0.0820 (down) 0.119 (Horiz.) 0.139 (Up)
0.02 |
Astro-E
3/16' Nominal (6.35mm)
.811 oz. per sq. ft. (207 g/m2)
15 Flame/30 Smoke
Class A/Class 1
None
63 lbs. per sq. in. (434 kPa)
14.5 (Down) 7.0 (Horiz.) 4.9 (Up)
0.03-0.04
0.96-0.97
0
0.0771 (down) 0.109 (Horiz.) 0.119 (Up)
0.02 |
|
HUD/FHA Projects: Meets HHI 1252B / California License: TF1213
/ California Registry: CAT213 (NJ) / Canada CMHC 11978
* These values are obtained in a C236 hot box test and represent
the R-Value of the cavity that includes the surround air spaces.
The measurements were made in a cavity framed with standard
2Óx4Ó lumber. For complete details regarding methodology,
contact your nearest innovative Energy Sales Office. ASTRO-FOILÕS
ability to reflect heat in open applications is not fully
measured by this test. ItÕs that extra reflective capability
that makes it possible for ASTRO-FOIL to keep people and animals
comfortable all year long.
|
Compliance
Agency/Organization |
ASTRO-FOIL
|
ASTRO-E
|
1995 CABO One and
Two Family Dwelling Code |
Section 319.1
|
Section 319.1
|
California Bureau of Home
Furnishings Insulation program
(Reg.No.) |
CA-T338
|
CA-T338
|
| City of Los Angeles |
RR-8403
|
RR-8403
|
Miami Dade County, Florida
Building Code and Product
Review Committee |
98-0413.01
|
98-0413.01
|
| Minnesota Dept. of Energy |
Yes
|
Yes
|
| 1999 National Building Code |
Section 803.4
|
Section 803.4
|
| 1997 Standard Building Code |
Section 803.2
|
Section 803.2
|
| 1997 Uniform Building Code |
Section 707.3
|
Section 707.3
|
WARNING: Reflective bubble-pack insulation will
ignite if exposed to fire or sufficient heat and intensity.
Protect insulation from exposure to open flame or other ignition
sources during shipping, storage and installation.
The manufacturer believes this information and
recommendations herein to be accurate and reliable. However,
since use conditions are not within its control the manufacturer
does not guarantee results from use of such products or other
information herein and disclaims all liability from any resulting
damage or loss. NO WARRANTY, EXPRESSED OR IMPLIED, IS GIVEN
AS TO THE MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE,
OR OTHERWISE WITH RESPECT TO THE PRODUCTS REFERRED TO. Freedom
from patents of PACTIV or others is not to be inferred.
Astro-Foil is a registered trademark of Pactiv
Corporation.
|
|
HEATING
& AIR CONDITIONING DUCTS
Installation Guidelines:
1 - Wrap ducts with 12", 16" or 24" wide ASTRO-FOIL.
Tape edges and corners with ASTRO-FOIL tape to hold it securely in place
and to create perfect vapor barrier.
2 - For extra efficiency band the duct with 2" wide strips of ASTRO-FOIL
spaced 24" apart and hold in place with foil tape. The additional
airspace between the duct and the ASTRO-FOIL will increase resistance
to heat loss or gain.
Works great with round duct pipes, too! Where access allows you may choose
to spiral-wrap the duct pipe.
More Efficient, Safer To Use and Easier
To Install Than Regular Bulk Mineral Fiber Or Foamboard Insulation For
Pre-Engineered Metal and Post-Frame Buildings
ASTRO-FOIL
is a revolutionary type of industrial, commercial
and general purpose insulation incorporating state-of-the-art
technology in design and manufacture. It includes a building code
approved vapor barrier, air infiltration barrier and powerful
insulation all in one.
Its unique composite design consists of layers of polyethylene
air bubble pockets, surrounded by a thin layer of reflective
aluminum foil that is inorganic, water-resistant, puncture-resistant,
termite and fungus resistant, non-allergenic and inhospitable to
nesting rodents.
ASTRO-FOIL is easy to installits thin, pliable, lightweight
design is especially suited for pre-engineered and post-frame
buildings. ASTRO-FOIL offers increased energy efficiency over traditional
insulation products. And its safe... there are no protective masks,
gloves or safety glasses required. Standard 4and 6 wide rolls
can be easily trimmed with a utility knife or pair of scissors to fit
any application. ASTRO-FOILs lightweight design makes it easy on
your
buildings design load.
Industrial Insulation
|
Residential Insulation
|
Reflective Foil Insulation
|
Radiant Barrier Insulation
|
Rigid Foam Board Insulation
|
Metal Building Insulation
|
Attic Insulation
|
Roof Insulation
|
Basement Insulation
|
HVAC Duct Insulation
|
Garage Door Insulation
|
Insulated Shipping Boxes
|
Insulated Shipping Products
|
Thermal Protective Packaging
|
Insulated Foil Packaging Pouches
|
Privacy Policy
|
Site Map
© Innovative Energy, Inc. 10653
W. 181st Ave. Lowell, IN 46356 phone
800.776.3645 fax 800.551.3645
|